Tooth 25: Two Canals, One Endodontic–Biomimetic Workflow

Nic
Nic
August 06, 2026

Case at a glance

Item

Detail

Tooth

Maxillary left second premolar, FDI 25

Procedure

Root canal treatment, followed by a biomimetic restoration

Canal anatomy

Two canals, both instrumented and obturated

Coronal preparation

VBlue R25

Apical preparation

GF File 25/06

Irrigation

2% NaOCl; passive ultrasonic irrigation with Ultra Smart AI (COXO); saline; 17% EDTA

Obturation

Gutta-percha with C-Root SP bioceramic sealer

Surface treatment

Aquacare Blue/White

Adhesive

All-Bond Universal

Reinforcement

EverX Flow D short-fibre-reinforced composite, plus Kerr resin coating

Build-up

Filtek One Bulk Fill Flowable A3 and Paste A2

Matrix and ring

Bioclear Biofit HD matrix, Strata-G ring

Restorative technique

Injection moulding with preheated composite in two consistencies, following the concept described by Dr David Clark

Why the irrigant and the coronal seal decide the outcome

Long-term success in endodontics is usually discussed in terms of cleaning, shaping and obturation. In practice, two other variables decide whether the treated tooth survives: how far the irrigant actually reaches beyond the prepared canal, and how well the coronal restoration keeps bacteria out afterwards.

Files create space. The irrigant disinfects that space. The sealer and the restoration protect it. None of these steps compensates for the one before it, which is why this case is presented as a chain rather than as a list of materials.

Step 1 — Shaping: coronal path first, apical geometry second

Coronal preparation came first with VBlue R25, opening straight-line access and removing the coronal interference that would otherwise steer the apical file. Only then was the apical third prepared with GF File 25/06.

The order matters more than it looks. When the apical preparation follows the coronal anatomy instead of a planned geometry, the terminal size and taper vary from canal to canal, and every later step inherits that variation: the master cone that has to fit, the sealer that has to fill, the irrigant that has to exchange at working length.

GF File 25/06 fixes that end point — a 25 tip size with a 06 taper, prepared in the apical third once the coronal path is already open.

• A defined apical box. The 25/06 geometry gives the master cone a matching seat and gives the irrigant a reproducible space to work in at length.

• A short apical sequence. With coronal flutes shaped first, the apical file reaches working length without the coronal third dictating its path.

• Repeatability. Rotary NiTi preparation holds size and taper steady from one canal to the next in the same tooth — the part a two-canal premolar makes easy to lose.

In a two-canal premolar, the second canal is easy to under-prepare. Working both to the same defined size and taper is the practical way to keep them at one standard before obturation.

Step 2 — Irrigation: dissolve, activate, then remove the smear layer

The protocol followed a simple logic: dissolve organic tissue first, remove the inorganic smear layer last, and activate the solution so it moves where instruments cannot.

1. 2% NaOCl. Tissue dissolution and antimicrobial action, with continuous volume exchange during instrumentation.

2. Passive ultrasonic irrigation, Ultra Smart AI (COXO). Acoustic activation moves the solution into fins, isthmuses and oval extensions that no file reaches. Activation is what turns irrigant sitting in the canal into irrigant doing work.

3. Saline. Intermediate flush that clears NaOCl before the chelator is introduced and limits interaction between the two solutions.

4. 17% EDTA. Removes the smear layer produced by instrumentation, opens the dentinal tubules, and leaves a surface the sealer can adapt to.

The sequence is the point. NaOCl needs contact time and exchange to dissolve tissue; the chelator works on a different substrate and comes last, after an intermediate saline flush.

Step 3 — Obturation: close the space the first two steps created

Both canals were obturated with gutta-percha and a bioceramic sealer, C-Root SP. Bioceramic sealers set hydraulically in the presence of moisture, which suits a canal that has just been rinsed, and they are used to fill the irregularities a cone cannot reach.

Obturation closes what shaping and irrigation opened. A well-adapted cone and a thin, complete sealer layer hold only if the apical preparation and the irrigation left a clean, defined canal; otherwise the sealer is compensating for a gap.

Step 4 — Biomimetic restoration: rebuild the tooth, do not plug it

The restorative stage was designed as a rebuild rather than a replacement: restore the missing dentine-like layer first, then rebuild enamel and contour over it, so occlusal load is distributed through the tooth instead of concentrating at the margins.

• Aquacare Blue/White — surface treatment ahead of the adhesive protocol.

• All-Bond Universal — universal adhesive step.

• Kerr resin coating — resin coating within the clinician's sequence.

• EverX Flow D — short-fibre-reinforced composite used as the dentine-replacement layer.

• Filtek One Bulk Fill Flowable A3 and Paste A2 — build-up and final contour.

• Bioclear Biofit HD matrix — anatomical matrix for contour and contacts.

• Strata-G ring — sectional ring for separation and a tight contact.

The build-up used the injection moulding technique described by Dr David Clark: preheated composite in two consistencies, injected into the matrix so the material adapts to the cavity walls and reproduces the anatomy with fewer voids than hand-condensed increments. The matrix sets the shape; the composite follows it.

Key takeaways

• The apical preparation is a design decision, not a routine step: it fixes what the cone fits, what the sealer fills and where the irrigant can reach.

• Irrigation counts when it is activated. PUI is what carries the solution past the prepared canal.

• Obturation quality is bounded by the preparation and the irrigation that preceded it.

• The coronal seal is part of endodontic success, not a separate restorative task. A biomimetic restoration is how that seal gets built.

• Choose the sequence before the instruments: coronal, apical, irrigate, obturate, rebuild.

Explore the GF File range and the GF File 25/06 specification on the product page.


Share on:

Related latest news

Consult
Consult
0755 26016056
E-mail
E-mail
TOP

Your privacy is important to us

We use cookies to personalize and enhance your browsing experience on our website. By clicking "Acceptall cookies", you agree to the use of cookies. You can read our Cookie Policy for more information.